TCM260904
Rev
0.1
TCM260904
Page 15 of 31
P
ROCEDURE FOR CHANGING OPERATION FREQUENCY
:
Step Action
Remark
1
Press EMS mushroom.
2
Turn key to “Off” position.
3
Depress and hold the pushbutton in accordance with the
frequency that you want to change.
Note:
The pushbutton must be depressed and held until step 6
is completed.
4
Turn key clockwise from “Off” to “On” position
5
Turn key counter-clockwise from “On” to “Off” position once
LED indicator is ceased flashing.
6 Compete
7
Power-On according to the proper procedure described
previously and return to normal operation.
1.
“Up” pushbutton
= Frequency A
2.
“Down” pushbutton
= Frequency B
3.
“East” pushbutton
= Frequency C
E
NTER PASSWORD OPERATION
(1)
Rotate “EMS” mushroom clockwise 45º and pull out.
(2)
Turn key clockwise to “ON” position.
(3)
Press the pushbutton sequentially to enter password within 10 seconds. (Remark: This time duration of
“Password Complete” can be set by software. At the duration of “Password Complete” the LED indicator will
flash with Green colour.)
(4)
The buzzer of transmitter will sound one-long sound to indicate the password is correct. After buzzer turns
off, Power-On according to the proper procedure and return to normal operation.
(5)
If password is incorrect then the buzzer will sound with two-short sound and one–long sound. Enter the
correct password again after buzzer is turned off.
Note 1: The function of password can be set by software in order to avoid unauthorized people to use remote controller.
Note 2: One must re-enter password to return to normal operation if EMS mushroom has been pressed (or “emergency stop”
signal has been transmitted due to transmitter auto power off).