Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide –
Preliminary Version
Page 24
A
Belden
Brand
CopperHead 3400 Camera Unit Back Side – Identifying Controls and Connectors
Area A – Connector Panel
For additional information about the signals carried on these
connectors please see Page 15
18) Time Code In (to Base Station)
Used to provide feed of local camera time code or for
the provision of a master synchronization time code
for all other cameras (typically from Camera 1 and only
if not master TC generator at base)
19) Time Code Out (from Base Station)
For time code synchronization of multi-camera
productions
20) VBS Out 2 (from Base Station)
Typically used for Genlock/Black Burst from master
synchronizing source
21) VBS Out 3 (from Base Station)
Typically used for Return Video to camera or for
Prompter feed
Area B – Camera Mounting Plate
The CopperHead 3400 Camera Unit is shipped with a variety of Battery Mount to camera types. The
Anton Bauer mount and the Sony V-mount are the most common. PAG and other battery mount systems
are available by special order. Please contact Telecast Fiber Systems or your authorized dealer.
Anton Bauer Camera Mounting Plate
V-Type Camera Mounting Plate
Summary of Contents for CopperHead 3400
Page 2: ......