Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide –
Preliminary Version
Page 51
A
Belden
Brand
5.2. Connections to the Copperhead 3400 Base Station
Figure 27 - CopperHead 3400 Base Unit Connections
Multi-Pin Cable Assemblies Used with the Copperhead 3400 Base Station
A) Camera Remote Control (Remote) Connector–
Connect either your camera manufacturers Camera Remote Control or the Telecast Fiber Universal
Controller – CHRCP-2050A or CHRCP-2050-LCD.
See Appendix 3 for a list of Telecast Fiber supplied cables
B) Data/GPI Connector
Connect a Remote Pan/Tilt/Zoom Control Unit and connect to one GPI Out and two GPI inputs.
Usage of GPI/Os other than Tally and Intercom control is outside of the scope of this User Guide.
Serial Control devices using RS232/422/485 can be controlled over this signal path.
See Page 92 for wiring details
C) Audio In Connector
Connect Intercom Program Audio and four Production Audio Channel outputs
See Page 93 for wiring details
D) Audio Out Connector
Carries audio back from the camera location – connect to an audio processing chain or monitors.
See Page 94 for wiring details