Model CFA-24 Transparent Cable Farm Automation Switch Reference Manual Page 7 of 76
Telebyte recommends the use of these web browsers:
Google Chrome v. 54.0.2840.71
Firefox Mozilla v. 49.0.2
Next Steps:
a.
If changing the factory default IP address to a new static IP, proceed to
Changing Factory Default IP
Address
later in this document.
b.
If powering down the unit, proceed to
Proper Shut Down Procedure
later in this document.
c.
If ready to continue to the next step in configuring the Standalone unit, proceed to
Definitions
.
3.3 Connecting CFA-24 to POE Switch
Example shows the CFA-POE-4 (8-port version). User may have the 16 or 24-port version.
1.
Plug the Linksys switch into a power source.
2.
Configure the remote PC with an IP address in the same subnet of the CFA’s IP.
3.
Connect a remote PC to the IN port of the POE adapter.
4.
Connect the CFA-24 to the POE port. Note: When configuring the first unit, connect only that CFA-24
to a POE port as shown in the diagram above. After that, additional units may be plugged in providing
they have a different IP address from any other CFA connected.
5.
Wait at least 75 seconds for the CFA-24 to boot up. An LED on the front of the unit turning from RED
to GREEN indicates the system is ready.
6.
From the remote PC, open a web browser and enter the factory default IP:
172.16.21.241
to
communicate with the CFA-24 unit.
7.
The Main screen is displayed.
8.
unit.
9.
The Main screen is displayed.
Next Steps:
a.
Proceed to
Changing Factory Default IP Address.