Input power R23-01, R23-02
R23-08, R23-09
R23-03, R23-04
Min.*
Max.**
Min.*
Max.**
Min.*
Max.**
115 V AC
15
45
19
48
15
56
230 V AC
11
25
13
27
10
30
12 V DC
105
355
143
390
105
455
24 V DC
55
188
76
203
55
237
Input power R23-11
R23-12
R23-13
R23-14
Min.*
Max.**
Min.*
Max.**
Min.*
Max.**
Min.*
Max.**
12 V AC
108
950
106
785
151
1000
150
695
24 V AC
55
388
55
332
75
405
75
317
48 V AC
35
265
35
210
45
270
45
190
115 V AC
16
90
16
80
20
90
20
70
230 V AC
11
47
12
42
15
50
13
35
12 V DC
109
740
109
645
147
780
144
502
24 V DC
58
379
57
330
80
400
76
260
*Minimum current consumption = Receiver powered, no active relays, no radio
session established.
**Maximum current consumption = Receiver powered, all relays on the receiver
active, radio session established.
IM-PN-RX107-CERT-01pre4
17