Product
type
Model
Safety requirement fulfilled
by the product
Achieved PL for the
system: R23 + model
Transmitter
PN-T19-2
EN ISO 13849-1:2015
Category 3 PL d
Cat 3 PL d
Receiver
PN-R15-xx
EN ISO 13849-1:2015
Category 3 PL d
Cat 3 PL d
Receiver
PN-R23-xx
EN ISO 13849-1:2015
Category 4 PL d
Cat 4 PL d
NOTE: Both the receiver and the transmitter used in the specific end-user system
must be compliant.
3 .3 Instal l ation
The stop relays on the receiver unit must be correctly installed on the end-user
system, to ensure that opened/deactivated stop relays interrupt the power to the
safety-related application. The safety level of the stop function can only be
credited when used in a complete end-user system that complies with EN
ISO 13849-1:2015 Category 4 PLd.
3 .4 C onf igu ration
The default configuration of the receiver unit complies with the appointed safety
requirements. Any reconfiguration that breaches the safety requirements will be
indicated by a LED on the main board of the receiver unit. Before commissioning
the radio system, the installer must check the LED indication.
Function LED
Status
Indicates
PLd status LED (red)
ON
Not compliant with PLd
OFF
Compliant with PLd
IM-PN-RX107-CERT-01pre4
13
PRELIMINARY