Specifications
1-14
RTX100B ISDB-T RF Signal Generator Service Manual
Table 1-5: Certifications and compliances (Cont.)
Category
Standards or description
Safety
Complies with the following safety standards/regulations:
UL 61010-1
Standard for Electrical Measuring and Test Equipment.
CAN/CSA C22.2 No.61010-1-04 Safety Requirements for Electrical Equipment for
Measurement, Control, and Laboratory Use.
EN 61010-1:2001
Safety Requirements for Electrical Equipment for
Measurement, Control, and Laboratory Use.
Installation (Overvoltage) Category Terminals on this product may have different installation (overvoltage) category designations. The
installation categories are:
CAT III
Distribution-level mains (usually permanently connected). Equipment at this level is
typically in a fixed industrial location.
CAT II
Local-level mains (wall sockets). Equipment at this level includes appliances,
portable tools, and similar products. Equipment is usually cord-connected.
CAT I
Secondary (signal level) or battery operated circuits of electronic equipment.
Overvoltage Category
Overvoltage Category II (as defined in IEC 61010-1)
Pollution Degree
A measure of the contaminates that could occur in the environment around and within a product.
Typically the internal environment inside a product is considered to be the same as the external.
Products should be used only in the environment for which they are rated.
Pollution Degree 1
No pollution or only dry, nonconductive pollution occurs. Products in this
category are generally encapsulated, hermetically sealed, or located in
clean rooms.
Pollution Degree 2
Normally only dry, nonconductive pollution occurs. Occasionally a
temporary conductivity that is caused by condensation must be expected.
This location is a typical office/home environment. Temporary
condensation occurs only when the product is out of service.
Pollution Degree 2
Conductive pollution, or dry, nonconductive pollution that becomes
conductive due to condensation. These are sheltered locations where
neither temperature nor humidity is controlled. The area is protected from
direct sunshine, rain, or direct wind.
Pollution Degree
Pullution Degree 2 (as defined in IEC 61010-1). Note: Rated for indoor use only.
IEC Characteristics
Equipment type:
Test and Measuring
Installation Category II (as defined in IEC 61010-1, Annex J)
Pollution Degree 2 (as defined in IEC 61010-1)
Safety Class I -- grounded product
Summary of Contents for RTX100B
Page 4: ......
Page 14: ...Service Safety Summary x RTX100B ISDB T RF Signal Generator Service Manual...
Page 16: ...Environmental Considerations xii RTX100B ISDB T RF Signal Generator Service Manual...
Page 21: ...Specifications...
Page 22: ......
Page 24: ...Product Overview 1 2 RTX100B ISDB T RF Signal Generator Service Manual...
Page 37: ...Theory of Operation...
Page 38: ......
Page 44: ...Theory of Operation 2 6 RTX100B ISDB T RF Signal Generator Service Manual...
Page 45: ...Performance Verification...
Page 46: ......
Page 95: ...Adjustment Procedures...
Page 96: ......
Page 100: ...Adjustment Procedures 4 4 RTX100B ISDB T RF Signal Generator Service Manual...
Page 101: ...Maintenance...
Page 102: ......
Page 151: ...Options...
Page 152: ......
Page 154: ...Options 6 2 RTX100B ISDB T RF Signal Generator Service Manual...
Page 155: ...Diagrams...
Page 156: ......
Page 158: ...Diagrams 7 2 RTX100B ISDB T RF Signal Generator Service Manual...
Page 160: ...7 4 RTX100B ISDB T RF Signal Generator Service Manual...
Page 162: ...7 6 RTX100B ISDB T RF Signal Generator Service Manual...
Page 163: ...Replaceable Parts List...
Page 164: ......