![Tektronix RTX100B Service Manual Download Page 150](http://html1.mh-extra.com/html/tektronix/rtx100b/rtx100b_service-manual_1077784150.webp)
Using the Rescue Disc
5-48
RTX100B ISDB-T RF Signal Generator Service Manual
2.
Connect the external USB DVD drive to port 1 and the USB keyboard to
port 2 of the instrument, and then restart.
After the BIOS screens, the CD boots and scans for the USB drive. A screen
is displayed within a short period prompting you to press 1 to continue and 2
to abort the procedure and turn off the instrument. By default, option 2 is
selected after a delay of 20 seconds.
3.
Press
1
to proceed as soon as you see the screen.
NOTE
. The approximate time taken to restore the Windows XP and RTX100B
application is 1 hr to 1.5 hr.
4.
Press any key to turn off the instrument once the restoration is complete.
5.
Disconnect the external USB DVD drive from the instrument and restart.
Phoenix Recover Pro 6 screen is displayed with
Recover Boot Partition
and
Recover Entire Drive
options.
6.
Click
Recover Entire Drive
to overwrite the entire data. A confirmation
dialog box is displayed. Click Yes to continue.
A recovery progress screen is displayed with the details of the time elapsed,
time remaining, amount of data recovered, and total data to recover. The
approximate time taken for the process is 1.5 hr.
CAUTION
.
Do not Cancel the recovery process once initiated. Cancelling the
process will leave your hard disk drive in a partially recovered unstable state.
Immediately after the data is recovered, the instrument restarts and the
Windows XP setup wizard is displayed.
7.
Click the
Next
button of the wizard until Windows XP is installed. The
instrument restarts after the installation of Windows XP to display the
RTX100B application screen.
NOTE
. On B020000 and above, the Application software (V10.1 and above) and
the test streams will have to be reinstalled after the Operating System recovery.
Summary of Contents for RTX100B
Page 4: ......
Page 14: ...Service Safety Summary x RTX100B ISDB T RF Signal Generator Service Manual...
Page 16: ...Environmental Considerations xii RTX100B ISDB T RF Signal Generator Service Manual...
Page 21: ...Specifications...
Page 22: ......
Page 24: ...Product Overview 1 2 RTX100B ISDB T RF Signal Generator Service Manual...
Page 37: ...Theory of Operation...
Page 38: ......
Page 44: ...Theory of Operation 2 6 RTX100B ISDB T RF Signal Generator Service Manual...
Page 45: ...Performance Verification...
Page 46: ......
Page 95: ...Adjustment Procedures...
Page 96: ......
Page 100: ...Adjustment Procedures 4 4 RTX100B ISDB T RF Signal Generator Service Manual...
Page 101: ...Maintenance...
Page 102: ......
Page 151: ...Options...
Page 152: ......
Page 154: ...Options 6 2 RTX100B ISDB T RF Signal Generator Service Manual...
Page 155: ...Diagrams...
Page 156: ......
Page 158: ...Diagrams 7 2 RTX100B ISDB T RF Signal Generator Service Manual...
Page 160: ...7 4 RTX100B ISDB T RF Signal Generator Service Manual...
Page 162: ...7 6 RTX100B ISDB T RF Signal Generator Service Manual...
Page 163: ...Replaceable Parts List...
Page 164: ......