Appendix B: GTS1063 CRPAT and CJTPAT Patterns
90
GTS1063 and GTS1250 GBIC Test Systems Instruction Manual
Table 26: CJTPAT Compliant Jitter Tolerance Pattern Data Sequence (Cont.)
D30.3 (7E)
D30.3 (7E)
D30.3 (7E)
D30.7 (FE)
1000
0111
0001
1110
0011
1000
0111
0001
1110
0001
E1
78
1C
8E
87
Cyclic Redundancy Check (CRC)
D21.7 (F5)
D14.1 (2E)
D22.7 (F6)
D29.6 (DD)
1010
1011
1001
1100
1001
0110
1000
0110
1110
0110
D5
39
69
61
67
End Of Frame (Pattern dependent EOFn)
K28.5 (BC)
D21.5 (B5)
D21.6 (D5)
D21.6 (D5)
1100
0001
0110
1010
1010
1010
1001
1010
1010
0110
83
56
55
59
65
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com