Performance Verification
GTS1063 and GTS1250 GBIC Test Systems Instruction Manual
61
Tx DATA to SYNC OUT Deterministic Jitter
If you performed the previous procedure, skip this procedure. This ten edge
deterministic jitter test is a lengthy test to perform manually, yet it provides an
accurate result for K28.5 deterministic jitter. If you desire a quicker check of
deterministic jitter, use the Fast Deterministic Jitter procedure on page 58.
Equipment
required
One sampling oscilloscope with an SD-22 sampling head
One Semi-rigid cable for sampling head
Two coaxial cables
Prerequisites
See page 43
1. Connect your wrist strap to the antistatic connector on the front of your
oscilloscope.
2. Connect an SMA cable between the the SYNC OUT of the GBIC Test
System and the oscilloscope Ext trigger input.
3. Connect an SMA cable between the Tx DATA output of the GBIC Test
System and the SD-22 input of the oscilloscope as shown in Figure 27.
Select K28.5
Tx pattern
Tektronix
1180C or
CSA80C
Oscilloscope
SD-22
Ext Trig input
GBIC Test
System
Tx DATA
Tx Sync
Figure 27: Tx Data Deterministic Jitter Test Setup
4. Set the GBIC Test System Transmit pattern to K28.5.
5. Perform the initial setup of the oscilloscope using the following steps:
a. Initialize the oscilloscope to default settings using the Initialize selector
which appears in the Utility major menu.
b. From the Trigger major menu, set the trigger source to external.
c.
Set the trigger level to 0.0 V; set the trigger polarity to positive edge.
d. Display the SD-22 channel.
e.
Set the Vertical Size to 100 mV/div.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com