55
Table 4: Using the RESET button
Desired Result
When to push the
RESET button
How long to hold the
RESET button in
Bypass DHCP/BOOTP
request and reset to last
configuration
During LAN discovery
loop (DHCP/BOOTP
request) when LAN-Link
is amber
momentarily
Reset only the password
to factory default (ad007)
Read the binary code of
the adapter IP address
on the status indicators
During normal operation
momentarily
Reset entire configura-
tion to factory defaults
During normal operation
or from power on
Until all indicators are
steady amber (
X
10
seconds)
Bypass DHCP/BOOTP and Reset to Last Configuration
To bypass DHCP/BOOTP and reset to the last configuration, do these
steps:
1. Power off the AD007 adapter and wait a few seconds.
2. Power on the AD007 adapter and wait until the adapter tries to
discover the LAN (the LAN light begins to blink green/amber
after the self test).
3. Using a small tool or end of a paper clip, momentarily push in the
reset button. This bypasses the LAN discovery (DHCP request).
4. When the LAN-Link indicator turns from amber to green, the
AD007 adapter has successfully loaded the last configuration.
Summary of Contents for AD007
Page 1: ...AD007 GPIB LAN Adapter User Manual 071 0245 01...
Page 4: ......
Page 10: ...Table of Contents vi AD007 User Manual...
Page 52: ...Getting Started 38 AD007 User Manual...
Page 76: ...Reference 62 AD007 User Manual...
Page 84: ...Appendix C Network Protocols 70 AD007 User Manual...
Page 90: ...Appendix D Troubleshooting 76 AD007 User Manual...
Page 94: ...Glossary 80 AD007 User Manual...
Page 98: ...Index 84 AD007 User Manual...