Operating Elements
3 optical keys for operator
Additional Features
Low Flow Cut-off, Oil and Water Content Analysis, Zero Calibration,
Flow Calibration, Long-Term Stability, Zero Point Adjustment,
Conforms IEC 61362 (Industrial) EMC Directive, Useful for all type
of sensors i.e. U-Tube, Nano, Standard
Temperature Range
Direct Mount
-60°F to 200°F (-50°C to 125°C)
Remote Mount
-300°F to 400°F (-180°C to 200°C)
2.4
Flow Ranges
2.4.1
Flow Ranges for Liquid (U-Tube)
Size (inch)
Allowable Flow
Range
(lb/min)
Normal Flow Range
for Accuracy 0.1%
(lb/min)
Normal Flow Range
for Accuracy 0.2%,
0.5%(lb/min)
1 ½”
12 - 1175
74 - 1175
56 - 1175
2”
19 - 1837
110 - 1837
92 - 1837
3”
52 - 5144
221 - 5144
203 - 5144
4”
74 - 7340
552 - 7348
441 - 7348
6”
184 - 18371
1287 - 18371
1103 - 18371
8”
368 - 36743
2572 - 36743
2573 - 36743
2.4.2
Flow Range for Liquid (Standard)
Size (inch)
Allowable Flow
Range
(lb/min)
Normal Flow Range
for Accuracy 0.1%
(lb/min)
Normal Flow Range
for Accuracy 0.2%,
0.5%
(lb/min)
½”
1 – 110
8 – 110
6 – 110
1”
3 – 293
23 – 293
15 – 293
1 ½”
9 – 881
89 – 881
42 – 881
2”
19 – 1837
184 – 1837
92 – 1837
3”
30 – 4409
294 – 4409
294 – 4409
4”
56 – 7348
552 – 7348
368 – 7348
6”
184 – 18371
1838 – 18371
919 – 18371
8”
368 – 36743
3674 – 36743