BA_ECO-Cube_190815_EN.docx
28
15.08.2019
13.1.2
Mounting and connecting the particle sensor
Mount the particle sensor in the cleaning device housing (pos. 2). A plug-in connection is locat-
ed there.
•
Open the service door (pos. 16).
•
Disassemble the protective plate (pos. A) by loosening the wing nut (pos. B)
.
•
Mount the particle sensor (pos. D) on the sensor base (pos.C). The mounting is carried
out by placing and turning a bit clockwise.
•
In the basic version a "cable bridge" (pos. E) is installed in the control housing (pos. 8).
It must be
removed
when using the particle sensor.
13.1.3
Behaviour in case of fire
1.
Keep calm.
2.
Initiate the internal and/or external rescue chain (fire brigade, etc.).
3. Immediately instruct all unauthorized people to leave the danger zone.
4. Disconnect the filter unit from the power supply.
5. Remove the lock pin of the extinguishing bottle.
6. Now actuate a rush extinguishing of 2-3 seconds by pulling the lever of the extinguishing
bottle.
Do not discharge the CO² bottle at once! Extinguishing in intervals is
more effective! A permanent blow off may lead to icing of the fire-extinguishing
equipment and to excessive release of CO² gas.
7. Wait during the reaction period, carry out visual inspection through the door window of the
service door (pos. 4), (visible pockets of embers or flames), then repeat number 6 if neces-
sary until the extinguishing is fully completed.
8. After the flames are extinguished the doors of the filter unit may only be opened by author-
ized persons. Wait at least 5 minutes before the opening.
Excessive release of CO² gas may lead to asphyxiation! Ventilate the
room after making sure that the fire has been extinguished.