10 Diagnostics and troubleshooting
A list of system errors is provided in the table. Error messages of the control system are explained
in their separate manual.
A recommissioning of the device must only occur if it is ensured that the filter system is functionally
equivalent to the original state. Repairs may only be carried out by TEKA personnel or, after con-
sultation with TEKA, by the personnel authorised by the operator.
Adhere to the instructions in the chapter "Safety instructions" and " Maintenance" when carrying
out any repairs. If in doubt, contact our service department:
Tel: +49 28 63 - 92 82 - 0
Fax: +49 28 63 - 92 82 - 72
Fault
Cause
Removal
System does not start.
The main switch (pos. 14) is in the
OFF position
Set the main switch in the ON
position.
Plug power supply is missing or
incorrectly inserted.
Plug connector check power
supply / plug in correctly.
No power at outlet.
Check the mains, remove error
if possible.
Dust at the dust collec-
tor (pos.6).
There is too much dust in the dust
collection container.
Empty the dust collection con-
tainer.
The toggle closures are not closed.
Close the toggle closures.
The seal of the dust collection con-
tainer is damaged.
The seal must be renewed.
The compressed air for the dedusting
is set too high.
Reduce the compressed air.
Dust at the service door
(pos.4).
One or more of the door lever is not
closed.
Close door lever.
The seal between the service door
and filter housing is damaged.
The seal must be replaced.
The compressed air for the dedusting
is set too high.
Reduce the compressed air
(see chapter 6.3).
Escape of dust at the hinge.
The hinge must be reoriented