BA_ECO-Cube_190815_EN.docx
23
15.08.2019
Suction power too low
(smoke hardly extract-
ed)
Filter elements are saturated.
Filter elements are saturated because
no compressed air is connected.
Filterpaket austauschen, Altfil-
ter ordnungsgemäß entsorgen!
Connect compressed air.
Damage at the capturing elements.
Replace the capturing ele-
ments.
The motor rotates in the wrong
direction.
Contact our service depart-
ment.
Clean air outlet contracted.
Check clean air outlet, if nec-
essary, fix error found.
Suction line contracted.
Check suction line, if neces-
sary, fix error found.
Throttle valve in the detection element
extraction hood is closed.
Open the throttle.
The unit is very noisy.
The motor rotates in the wrong
direction.
Contact our service depart-
ment.
The curved silencer (pos.10) is not
mounted.
Mount the curved silencer.
The intake or exhaust air pipes are
not mounted.
Mount the pipelines.
The filter unit is untight.
Check where the unit is un-
tight.