3-14
LED
Display: parameter/parameter value/frequency/line speed/DC
voltage/output voltage/output current/PID feedback/input and
output terminal status/Heat sink temperature/Program
Version/Fault Log.
Display
LED Status Indicator
For run/stop/forward and reverse.
Overload Protection
Integrated motor and Inverter overload protection.
Over voltage
100V/200V : Over 410V, 400V : Over 820V
Under voltage
100V/200V : Under 190V, 400V : Under 380V
Momentary Power Loss
Restart
Inverter auto-restart after a momentary power loss.
Stall Prevention
Stall prevention for Acceleration/ Deceleration/ and
continuous Run.
Short-circuit output
terminal
Electronic Circuit Protection
Protective
Functions
Grounding Fault
Electronic Circuit Protection
Other protective
functions
Overheat protection, carrier frequency following as temperature
decreases, fault contact output, reverse limitation, unattended
start protection (USP) , times of automatic reset setting,
parameters locking and etc.
Protective
functions
International
authentication
CE/UL
communication control
Standard built in RS485 communication (Modbus), and it can
make control at one to one or one to more.
Operating temperature
-10~50
℃
Storage temperature
-20~60
℃
Humidity
under 95%RH ( no condensation)
Shock
Under 20Hz, 1G(9.8m/s²)20
~
50Hz 0.6G(5.88m/s²)
Specifications of EMC
complying with the first type of environment of EN61800-3
Specifications of LVD
complying with the demand of EN50178
Security level
UL508C
Environment
Protection level
IP20