4-60
Range
【
0~65535
】
Days
13- 05
Accumulated Inverter Operation Time Mode
Range
【
0
】
:Power on time
【
1
】
:Operation time
¾
When the operation time recorded in accumulator 1(Parameter 13-03) reaches 24 hours
¾
The recorded value in accumulator 2 parameter 13-04 changes to 1 day and the value in
accumulator 1 is reset to 0000.
13- 06
Parameter lock
Range
【
0
】
:Enable all Functions
【
1
】
: Preset speeds 05- 01~05- 08 cannot be changed
【
2
】
:All Functions cannot be changed Except for preset speeds set in 05-
01~05- 08
【
3
】
:Disable All Function Except 13-06
¾
When the 13-07=00000 (not set a password), you can adjust the parameters 05-01~05-08 from
13-06.
13- 07
Parameter Lock Key Code
Range
【
00000~65535
】
¾
When a parameter lock key number is entered in parameter 13-07. For any parameter
modification the key number has to be entered.
See following Parameter lock key setting example:-
¾
Setting Parameter lock key number example:-
Step1:
1st entry
▲
▼
or
</ENT
</ENT
Step2:
2nd
entry
</ENT
▲
▼
or
</ENT
Set Password successfully
Set Password failed
▲
▼
or
</ENT
Key code ( password) unlock