5-11
Encoder
pulse
Scalling
Encoder
CN2
CN1
Servo Drive
(Speed Control)
Encoder
Signal
Host Controllor
(Position Control)
Analog Speed
Command
Scaled Output
Pulse
5-3-4 Analog Reference for Speed Command Limit
A maximum limit for analog speed can be set by Sn218.
Parameter
Name
Default
Unit
Setting range
Control mode
Sn218
Analog speed
command limit
Rated rpm
x 1.02
rpm 100~4500
S
5-3-5 Encoder Signal Output
Servo motor encoder pulse signal can be output to a host controller to establish an external control
loop.
Set the required encoder Pulse Per Revolution (PPR) in parameter Cn005.
Default output value is the actual encoder PPR.
Parameter
Name
Default
Unit
Setting range
Control
mode
2500
8192
★
Cn005
Encoder pulse
output scale
32768
pulse
1~ Encoder PPR
ALL
New setting will become effective after re-cycling the power.
Encoder pulse output terminal description:
Pin
Name
Pin NO. of
CN1
Control
mode
PA
Encoder pulse output A Phase
signal
CN1-35
/PA
Encoder pulse output /A Phase
signal
CN1-36
PB
Encoder pulse output B Phase
signal
CN1-37
/PB
Encoder pulse output /B Phase
signal
CN1-38
PZ
Encoder pulse output Z Phase
signal
CN1-39
/PZ
Encoder pulse output /Z Phase
signal
CN1-40
ALL
Summary of Contents for JSDAP Series
Page 1: ......
Page 17: ...1 11 1 2 Surface and Panel Board JSDAP 10A 15A 20A 30A JSDAP 50A3 75A3 100A3 25B 35B 50B ...
Page 21: ...1 15 1 4 2 Direction and Distance ...
Page 25: ...2 2 400V Class ...
Page 98: ...5 12 PA PB PZ 90 PA PB PZ 90 TIME A leads B CW CCW B leads A TIME ...
Page 236: ...9 5 Dimensions for JSDAP 150A3 75B 100B Dimensions for JSDAP 200A3 300A3 ...
Page 249: ...A 1 Appendix A Accessories ...
Page 250: ...A 2 ...
Page 251: ...A 3 ...
Page 255: ......