4-2
4-1 Trial Operation for Servomotor without Load
To carry out a successful trial run follow the steps below and ensure that drive wiring is correct and as
specified.
1. Installation of servo motor.
Ensure that the motor is installed securely so that there is no movement and vibration during trial run.
2. Wiring.
Check servo drive
、
motor power connections and motor encoder connection.
No control signal wiring is required of this stage thus remove connector (CN1) from the servo drive.
3. Servo drive power.
Apply power to servo drive. If the display showed any Alarm message as below, please refer to chapter 8
to identify the cause.
The above is caused by Input terminals
CCWL (Counter clockwise Limit)
and
CWL (Clockwise Limit)
being activated
at the same time. See (the default setting of high or low input logic state according to the
description in section 5-6-1 ). Because of the alarm, the servo can not operate normally.
Set the parameter
Cn002.1=1
to disable the drive limit function temporarily during trial run period.
In order to prevent potential damage,prior to trial run ensure that the driven
mechanism, couplings and belts etc are disconnected from the motor.
Summary of Contents for JSDAP Series
Page 1: ......
Page 17: ...1 11 1 2 Surface and Panel Board JSDAP 10A 15A 20A 30A JSDAP 50A3 75A3 100A3 25B 35B 50B ...
Page 21: ...1 15 1 4 2 Direction and Distance ...
Page 25: ...2 2 400V Class ...
Page 98: ...5 12 PA PB PZ 90 PA PB PZ 90 TIME A leads B CW CCW B leads A TIME ...
Page 236: ...9 5 Dimensions for JSDAP 150A3 75B 100B Dimensions for JSDAP 200A3 300A3 ...
Page 249: ...A 1 Appendix A Accessories ...
Page 250: ...A 2 ...
Page 251: ...A 3 ...
Page 255: ......