7-
9
ASCII Mode Framing
Symbol
Name
Description
STX
Comm. start
3AH, Char ’:‘
ADR Slave
address
Include 2 ASCII code within 1-byte
Comm. add : 1 ~ 254 convert to Hex representation ;
Ex. Servo drive ADR is No.20 convert to 14H ;
ADR = ’1‘ , ‘4’
→
’1‘ = 31H , ‘4’ = 34H
Function Code
Function code
Include 2 ASCII code within 1-byte
Function codes :
03H : Read the register contents,
06H : Write Single Register , 08H : Diagnostic function,
10H : Write Multipile Registers
DATA(n-1)
│
DATA(0)
Data
n-word = 2n-byte (ASCII numbers : 4n ), n
≦
30
The format of data is depend on Function code
LRC
Check code
Include 2 ASCII code within 1-byte
END 1
END 1 (CR)
0DH
;
Char ’ \ r ‘
END 0
END 0 (LF)
0AH
;
Char ’ \ n ‘
RTU Mode
Symbol
Name
Description
STX
Comm. start
Excess comm. loss time setting 10ms
ADR Slave
address
1-byte
Comm. address : 1 ~ 254
,
convert to Hex representation ;
Ex. Comm. address = 20 convert representation to 14 Hex, ADR
= ’14H’
Function Code
Function code
1-byte
Function codes :
03H : Read the register contents,
06H : Write Single Register , 08H
:
Diagnostic function,
10H : Write Multipile Registers
DATA(n-1)
│
DATA(0)
Data
n-word = 2n-byte
;
n
≦
30
The format of data is depend on Function code
CRC-Low Checking
code-LO
1-byte
CRC-High Checking
code-HI
1-byte
END 0
End 0
Excess comm. loss time setting 10ms
Summary of Contents for JSDAP Series
Page 1: ......
Page 17: ...1 11 1 2 Surface and Panel Board JSDAP 10A 15A 20A 30A JSDAP 50A3 75A3 100A3 25B 35B 50B ...
Page 21: ...1 15 1 4 2 Direction and Distance ...
Page 25: ...2 2 400V Class ...
Page 98: ...5 12 PA PB PZ 90 PA PB PZ 90 TIME A leads B CW CCW B leads A TIME ...
Page 236: ...9 5 Dimensions for JSDAP 150A3 75B 100B Dimensions for JSDAP 200A3 300A3 ...
Page 249: ...A 1 Appendix A Accessories ...
Page 250: ...A 2 ...
Page 251: ...A 3 ...
Page 255: ......