6
3
MARKING OF PRUDOCT
A Nameplate is affixed on the front of the unit, showing:
•
Manufacturer information
•
EC mark stamp
•
Model
•
Serial number
•
Year of construction
•
Voltage
•
Hydraulic loading
Fig. 3-1 - Nameplate
Fig. 3-2 – Mark label
A wheel mark label, attached close to the nameplate, with the identification of the Notified Body and followed by the year in
which the mark is affixed.
4
PLACARD
ATTENTION
THE INSTALLATION PROCEDURES EXPOSE THE INSTALLER TO HIGH VOLTAGE AND ELECTRICAL
SHOCK HAZARD. ONLY ATTEMPT INSTALLATION IF YOU ARE A QUALIFIED TECHNICIAN AND
ONLY IF SURROUNDING CONDITIONS ARE SAFE.
DO NOT USE ANY FILTERS ALONG ALL THE AIR RELIEF LINE.
MAKE SURE ALL ANTI-SIPHON VALVES ARE PROPERLY INSTALLED.
CHECK ALL HYDRAULIC PIPES/HOSES ARE PROPERLY FIXED.
CHECK ALL ELECTRICAL CABLES ARE PROPERLY WIRED.
CHECK ROTATION OF ALL MOTORS ACCORDING TO THEIR ARROWS.
USE A CIRCUIT BREAKER IN ORDER TO AVOID OVERLOAD. ITS SIZE DEPENDS ON ELECTRICAL
CONSUMPTION OF THE UNIT.
5
TREATMENT CAPACITY
Marine Sanitation Device
ECOmar20 S
ECOmar 32 S
ECOmar 45 S
ECOmar 70 S ECOmar 145 S
Average capacity per day (lt.)
1500
2400
3375
5250
10875
Peak capacity per day (lt.)*
2000
3200
4500
7000
14500
Average capacity per hour (lt.)
62.5
100
140.625
218.75
453.125
Peak capacity per hour (lt.)
83.3
133.3
187.5
291.67
604.17
Sewage capacity treated per cycle (lt.)
33.75
52.8
66.5
107.865
241.5
Seawater / brackish water / fresh water load
per cycle (lt.) ***
24.3
38.016
47.88
71.91
124.2
Total volume per cycle (lt.)
58.05
90.816
114.38
179.775
365.7
Persons**, if
passenger ships
Without vacuum plant
8
14
19
30
63
With vacuum plant
10
17
24
37
78
Persons**, if
other ships
Without vacuum plant
11
17
25
38
80
With vacuum plant
14
23
33
51
107
Condition of heel up to
(max angle of pitch and roll)
22.5°
Range of environmental temperature
0°C ÷ 55°C
Humidity
95%
Salinity
55000 ppm
*System running 24 hours per day.
**Indicative maximum persons number, at peak treatment capacity per day (system running 24h/24h). Ask to Tecnicomar S.P.A. for a proper plant sizing.
***Designed to operate in salt, brackish and fresh water.