33
From this screen you can change each parameter of the system, by do the following steps:
-
Press the arrow keys ▲/F1-AUTO and down ▼/F2-MAN to change the value of the parameter displayed;
-
Press the "START/ENTER" or "STOP/ESC" key to update the displayed desired value;
-
Press the "STOP/ESC" key to return to the previous parameter;
-
Press the "START/ENTER" key to go to the next parameter;
-
Power down the unit and then power up the unit, using the emergency stop button;
-
At this point starts an initializing phase lasting few seconds, during which the screen show the firmware release;
-
Now the electronic card will be operational with the new set parameters.
In particular the PCB control panel manages fifteen parameters, each of which manages a particular aspect of the system
functioning. For more details about the functional description of each parameter refer to the list below.
ECOmar S Parameters List:
01)
Display Language (0=I, 1=E, 2=C): allows to choose the display language between Italian, English and Russian (Cyrillic).
02)
Dosing Timer (sec.): allows to set the dosing pumps activation time per cycle, according to the model (do not change).
03)
Maceration Timer (min.): allows to set the maceration time per cycle (do not change).
04)
Discharge Timer (sec.): allows to set the clarified water discharge time per cycle (adjust according to discharge distance).
05)
Washing Timer (sec): allows to set the treatment tank washing time per cycle (do not change).
06)
Washing Option (0=B, 1=L, 2=E): allows to choose the factory set washing mode (do not change).
07)
Failure Delay (sec.): allows to set a fault holding time after which each alarm is managed (do not change).
08)
Discharge Valve (V1) Delay (sec.): allows to set the time necessary for the activation of the valve V1 (do not change).
09)
Filling Failure Alarm (min.): allows to set a filling time after which the
Filling Alarm
occurs (do not change).
10)
Sea-water Failure Alarm (min.): allows to set a dilution time after which the
Seawater Alarm
occurs (do not change).
11)
Display Backlight Timer (sec): allows to set the display backlight time (when set to 0 the display never lights off).
12)
Dosing Option (0=L, 1=B): allows to choose the factory set dosing mode (do not change).
13)
Flocculation Timer (sec): allows to set the flocculation time per cycle (do not change).
14)
Sludge Discharge Valve (V2) Delay (sec): allows to set the time needed for sludge valve V2 activation (do not change).
15)
Sludge Discharge Timer (sec): allows to set the sludge discharge time, according model (adjust according distance).
The factory setting values of each parameter are record in the attached Test Report. For the string shown on the display of the
Main Control Box, for each parameter refer to the table here below as an example of that reported on the Test Report.
P/N
PARAMETER
Setting Value Unit
Note
01.
Lang (0=I,1=E,2=C):
0; 1; 2
0 : = Italian, 1 : = English, 2 : = Russian (Cyrillic)
02.
DOSING_T (s):
sec.
H
2
O
2
pump: % ECOFLOC pump: %
03.
MACERATING_T (m):
min
04.
DISCHARGE_T (s):
sec.
05.
WASHING_T (s):
sec.
06.
WASH. (0=B,1=L,2=E):
0; 1; 2
07.
FAILURE_DLY (s):
sec.
08.
3WAY_V1_T (s):
sec.
09.
FIL_FLT_T (m):
min.
10.
SEA_FLT_T (m):
min.
11.
BACKLIGHT (s):
sec.
12.
TY DOS (0=L,1=B):
0; 1
13.
T_FLOC (s):
sec.
14.
3WAY_V2_T (s):
sec.
15.
DISCH_SLUDGE_T (s):
sec.
Table.9.1.1 – Parameters Settings table from the plant TEST REPORT