Page
34
sur
47
TRAÇABILITÉ CRÉATIVE
CREATIVE TRACEABILITY
www.technomark-marking.com
Modèle du 29/10/2015
TECHNOMARK
3 Allée Michaël FARADAY
Parc d’activités STELYTEC
42400 SAINT-CHAMOND (France)
Tel : +33 (0) 4 77 22 25 91
Fax : + 33 (0) 4 77 22 38 93
E-mail : [email protected]
Illustration 18 : Maintenance window
IDI Track
: enable or disable the IDI track function of mechanical surveillance.
This function controls some mechanical breakdown:
Broken stylus
Marking without part
Stylus Lubrication
In the case of marking without part or broken stylus, an error message appears with output activation if need be.
In the case of a lack of lubrication, a maintenance problem is created and the lubrication LED becomes red.
Lubrication
: the LED turns ref if your machine requires lubrication. (Every 500000 impacts or IDI track
problem if the function is activated). Once the stylus is lubricated, press the key 1 of the keyboard to remove
the alarm.
XY revision: the LED turns red if your machine requires an X and Y axis revision. (10000 meters traveled)
General revision: the LED turns red if your machine requires a general revision. (the machine has been
marking for 1000 hours)
Maintenance required: the LED turns red if your machine requires a return to workshop. (after 1 year of
working)
Z axis revision: the LED turns red if the machine requires a Z axis. (10000 meter traveled)
Use the button
to confirm your modifications or
to cancel them.
If it is activated, it is however automatically disable in the case of a marking with low forces (1 or 2).