7.6.
IDI
calibration
The functionality IDI can be calibrated with this procedure in case of machine maintenance or factory settings
modification.
This procedure consists in four successive similar steps in which a marking point is made with different heights.
The different heights to calibrate are the followings: 1mm, 2.5mm, 5mm, and 6.5mm.
Each step is shown by the following window:
Illustration 22 : IDI Calibration
Enter the X and Y position where the marking point will be made and place to the written height.
Then confirm with
to make the impact and go to the next step.
The IDI function is calibrated in factory at the delivery and the IDI calibration procedure is recommended if you
change the marking head or its cable.