Zeros marked
allows selecting if zeros beginning a serial number are marked or not. If so, 001 will be marked as 001,
otherwise 001 will be marked as 1.
It’s possible to reset the serial number automatically. Several choices for this function are possible:
None:
the serial number isn’t reset.
Day
: the serial number is reset every day.
Value
: the serial number is reset when it reaches the
maximum
value defined in
ending at
.
Team:
the serial number is reset for each team change. (see
teams
)
Week:
the serial number is reset each week.
The field
starting at
is the value given to the serial number when it is reset. The field
ending at
corresponds with the
maximum value used when we want a reset on the
Value
criteria.
Once again, the
number of digits
is essential for the
starting at
and
end at
fields. There must be coherence and
therefore
the same number of digits for all these data
.
It should be noted that
all blank fields
have to be filled up, otherwise an error will appear when confirming with
.
The serial number
SHARED
is a specific serial number. Share by all files of the machine, you can’t delete it.
Its
current value and its parameters
are valid for
all the
files where it is used.
5.3.2.
Add
a
variable
A
variable
is a
non frozen text
with fixed parameters which can be changed at each marking. Either manually, or with
a bar code reader connected to the machine.
Variables are defined for one file except for the VSHARED variable common to all the files.
When a variable is inserted in a marking line, it’s the value of this variable which is marked.
A scrolling menu allows choosing among the variables:
Create a new variable
Use the VSHARED variable
Use an existing variable
Use a bar code variable