Installing the Security System
33
Table 2: Security Zone Functions
Zone Func-
tion
Tamper
Armed
Faulted
Unarmed
Faulted
Arm Away
Faulted
Arm Stay
Faulted
Arm Night
Comments
Entry/Exit
Alarms
No action
taken
Initiates
entry delay.
Alarms if
entry delay
expires.
Initiates
entry delay.
Alarms if
entry delay
expires.
Alarms
immediately
For doorways
that are used to
enter the
premises.
When the
system is
armed, faulting
this type of
sensor starts an
Entry Delay
countdown
(except in arm
night mode)
rather than
sending an
immediate
alarm.
Default function
for
Door/Window
sensors.
Perimeter
Alarms
No action
taken
Alarms
Immediately
Alarms
immediately
Alarms
immediately
If faulted when
the system is
armed or during
an Entry/Exit
Delay, an alarm
is tripped.
Default function
for glass break
sensors. Also
available for
Door/Window
sensors
Interior
Follow
Alarms
No action
taken
Alarms
Immediately
No action
taken
No action
taken
Monitors the
internal living
spaces of the
premises and
trigger an