3
Indoor Unit MCAV97R5VAA
Outdoor Unit GRV99R5VAA
Power Source 220–240V ~ 50Hz
Voltage rating 230 V
Performance Cooling Heating
Capacity kW 2.65 3.5
BTU/h 9,037 11,93
Air circulation (High) m
3
/h 430
Moisture removal (High) Liters/h 0.8 —
Electrical Rating Cooling Heating
Available voltage range V 198 ~ 264
Running amperes A 4.7 4.6
Power input W 1030 1050
Power factor % 95 96
C.O.P. W/W 2.6 3.4
Compressor locked rotor amperes A 24 24
Features
Controls / Temperature control Microprocessor / I.C. thermostat
Control unit Wireless remote control unit
Timer ON/OFF 24 hours & Daily program,1-hour OFF
Fan speeds Indoor / Outdoor 3 and Auto / 1(Hi)
Airflow direction (Indoor) Horizontal Manual
Vertical Auto
Air filter Washable, Anti-Mold
Compressor Rotary (Hermetic)
Refrigerant / Amount charged at shipment g R407c / 990
Refrigerant control Capillary tube
Operation sound Indoor : Hi / Me / Lo dB-A 37 / 32 / 31 37 / 32 / 31
Outdoor : Hi dB-A 43 45
Refrigerant tubing connections Flare type
Max. allowable tubing length at shipment m 7.5
Refrigerant Narrow tube mm (in.) 6.35(1/4)
tube diameter Wide tube mm (in.) 9.52(3/8)
Refrigerant tube kit / Accessories Optional / Air Clean Filter
Dimensions & Weight Indoor Unit Outdoor Unit
Unit dimensions Height mm 270 540
Width mm 805 700
Depth mm 177 265
Package dimensions Height mm 243 568
Width mm 855 815
Depth mm 332 343
Weight Net kg 8.0 36.0
Shipping kg 10.0 39.0
Shipping volume m
3
0.07 0.16
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
Rating conditions are:
Cooling : Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Heating : Indoor air temperature 20°C D.B.
Outdoor air temperature 7°C D.B. / 6°C W.B.