31
6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor Unit MCAV77R5VAA
Outdoor Unit GRV79R5VAA
COOLING
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230V 1-phase 50Hz
Rating Conditions Running Amps. A 0.11 0.24 3.35 3.7
Power Input kW 0.025 0.055 0.74 0.82
Full Load Conditions Running Amps. A 0.11 0.24 4.05 4.4
Power Input kW 0.025 0.055 0.86 0.94
Rating Conditions : Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
HEATING
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230V 1-phase 50Hz
Rating Conditions Running Amps. A 0.11 0.24 3.05 3.4
Power Input kW 0.025 0.055 0.671 0.75
Full Load Conditions Running Amps. A 0.11 0.24 3.65 4.0
Power Input kW 0.025 0.055 0.801 0.88
Rating Conditions : Indoor Air Temperature 20°C D.B.
Outdoor Air Temperature 7°C D.B. / 6°C W.B.
Full Load Conditions : Indoor Air Temperature 27°C D.B.
Outdoor Air Temperature 24°C D.B. / 18°C W.B.