MEAN WELL
SWITCHING POWER SUPPLY
ISO-9001 CERTIFIED MANUFACTURER
S-60
SERIES
.
LOW COST, HIGH RELIABILITY
.
COMPACT SIZE, LIGHT WEIGHT
.
105
º
C
OUTPUT CAPACITOR
.
100% FULL LOAD BURN-IN TEST
.
INTERNATIONAL AC INPUT RANGE
.
BUILT IN EMI FILTER, LOW RIPPLE NOISE
.
HIGH EFFICIENCY, LOW WORKING TEMPERATURE
.
SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT
.
SHORT CIRCUIT, OVERLOAD, OVER VOLTAGE PROTECTED
MODEL
SPECIFICATION
S-60-5
S-60-12
S-60-15
S-60-24
DC OUTPUT VOLTAGE
5V
12V
15V
24V
OUTPUT V. TOLERANCE
±2%
±1%
±1%
±1%
OUTPUT RATED CURRENT
12A
5A
4A
2.5A
OUTPUT CURRENT RANGE
0-12A
0-5A
0-4A
0-2.5A
RIPPLE & NOISE
120mVp-p
120mVp-p
150mVp-p
150mVp-p
LINE REGULATION
±0.5%
±0.5%
±0.5%
±0.5%
LOAD REGULATION
±1%
±0.5%
±0.5%
±0.5%
DC OUTPUT POWER
60W
60W
60W
60W
EFFICIENCY
73%
76%
77%
79%
DC VOLTAGE ADJ.
+10,-5%
±10%
±10%
±10%
INPUT VOLTAGE RANGE
85
~
264VAC
47
~
63Hz;
120
~
370VDC
AC CURRENT
2A/115V
1A/230V
INRUSH CURRENT
COLD START
30A/115V
60A/230V
LEAKAGE CURRENT
<3.5mA/240VAC
OVERLOAD PROTECTION
105%
~
150%
TYPE:PULSING HICCUP SHUTDOWN
RESET:AUTO RECOVERY
OVER VOLTAGE PROTECTION
115%
~
135%
OVER TEMP. PROTECTION
----------
TEMP. COEFFICIENT
±0.03% /
º
C
(0
~
50
º
C)
SETUP, RISE, HOLD UP TIME
800ms, 50ms, 10ms / 115VAC
300ms, 50ms, 80ms / 230VAC
VIBRATION
10
~
500Hz, 2G
10min./1cycle, PERIOD FOR 60min. EACH AXES
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms
WORKING TEMP., HUMIDITY
-10
º
C
~
+60
º
C(REFER TO OUTPUT DERATING CURVE), 20%
~
90% RH
STORAGE TEMP., HUMIDITY
-20
º
C
~
+85
º
C, 10%
~
95% RH
DIMENSION
159
*
97
*
38mm
CASE:901
WEIGHT
0.55Kgs
SAFETY STANDARDS
UL1012, TUV EN60950, IEC950, UL1950 APPROVED
EMC STANDARDS
CISPR22 (EN55022), IEC801-2,3,4, IEC555-2 VERIFICATION
NOTE
:
1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25
º
C
70% RH. AMBIENT.
2.TOLERANCE
G
INCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION.
3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR.
4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD.
5.LOAD REGULATION IS MEASURED FROM 0% TO 100% RATED LOAD.
6.C2,3,6 MUST BE REMOVED.
2000-10-03
Summary of Contents for TAUD-100
Page 1: ...TAUD 1000 BROADCAST TRANSMITTER OPERATING MANUAL ...
Page 34: ......
Page 35: ......
Page 49: ......
Page 50: ......
Page 52: ...Technalogix Ltd Adrenaline Control System VI 31 Temp sensor 1 11 component layout Top ...
Page 53: ...Technalogix Ltd Adrenaline Control System VI 32 Temp sensor 1 11 component layout bottom ...
Page 58: ......
Page 59: ......
Page 62: ......
Page 63: ......
Page 69: ...Technalogix Ltd Adrenaline Control System VI 66 SNMP Configuration ...