Technalogix Ltd
Adrenaline Control System
VI-69
SNMP
The Technalogix.mib file allows access to the following
Read Only
Dip switch Setting
- 8 bit value from dipswitch
Pallet Supply Voltage
- voltage level (Vdc)
Temperature
-
temperature
in
(°C)
12V Current
- current on12V bus (Adc)
48V Current
- current on high voltage bus (Adc)
Attenuation
-
attenuation
level
Forward Level
- forward level as % rated full scale
Reflected Level
- reflected level as % rated full scale
RF Input Level
- input level as % rated full scale
RF Fault
- hardware fault flag
Run Time
- time since start up or reset
Serial
Number
Model
Number
SNMP Error Flag
- error flag, also for trap (see below)
VSWR Flag
- error flag for high VSWR
Overdrive
- error flag for overdrive
Temperature Flag
- error flag for high temperature
Read/Write
AGC mode
- 1 AGC on / 0 AGC off
Reset
- 1 Reset System 0 normal
Carrier On/Off - 1 Carrier On
0 Carrier Off
Carrier Up
- 1 Increase Carrier Level
Carrier Down - 1 Decrease Carrier Level
VSWR
- 1-8 set VSWR between 1.1 and 1.8:1
Read and Write communities can be set from the web interface.
Summary of Contents for TAUD-100
Page 1: ...TAUD 1000 BROADCAST TRANSMITTER OPERATING MANUAL ...
Page 34: ......
Page 35: ......
Page 49: ......
Page 50: ......
Page 52: ...Technalogix Ltd Adrenaline Control System VI 31 Temp sensor 1 11 component layout Top ...
Page 53: ...Technalogix Ltd Adrenaline Control System VI 32 Temp sensor 1 11 component layout bottom ...
Page 58: ......
Page 59: ......
Page 62: ......
Page 63: ......
Page 69: ...Technalogix Ltd Adrenaline Control System VI 66 SNMP Configuration ...