Technalogix Ltd
Adrenaline Control System
VI-15
Power Supplies Screen
This screen allows the user to view individual voltage and current readings. The Power Supplies
Screen is displayed below:
DC supply voltages are nominally 30 or 48Vdc depending on the system. Readings of this
voltage in the Power Supplies Screen, and on the summary bar at the bottom of the
touchscreen, should not vary more than +/- 2%.
If multiple amplifier pallets are included in the amplifier chain, then the individual currents will all
be displayed in the Currents section of the screen. In the case of multiple pallets in the chain,
typically the user should see matching of the final pallets to within approximately 10%. Anything
outside this range is usually a sign that there may be an issue. Transistor device or circulator /
isolator load damage could be the culprit, or the tragic spilt-drink-on-transmitter incident. Our
team would be glad to walk you through any troubleshooting issues or questions you may have.