III-4
After amplification, the signal exits the power amplifier enclosure and goes into the filter/coupler
enclosure. The two RF signals from each of the TAUD-500 amplifiers (500-watts RMS) get
combined by a 2-way, 90 degree combiner via phased cables. The amplified signals are filtered
with a bandpass filter and monitored again with another directional coupler before heading out
to the customers inline 8VSB reading wattmeter and then to an antenna for broadcast, as
depicted in the following filter/coupler block diagram.