Technalogix Ltd
Adrenaline Control System
VI-17
History Screen
The History Screen provides a summary of the most recent events that have occurred in the
power amplifier, including the date and time of occurrence. An event can either be a fault or
simply an action like turning on or off the carrier. The format of the History Screen is illustrated
below:
Ten of the most recent events are displayed on the History Screen. As more events occur, the
earliest recorded event gets displaced on the screen. If the user changes the time and/or date
from the Date and Time Screen, then the events that occurred before the time and/or date
change remain unchanged with their original time stamp.
The user can clear the history screen by pressing the CLEAR HISTORY. Users will find this
screen useful in correlating events in the power amplifier with external events like weather and
changes to the broadcast facility’s environment.
The events are recorded in non-volatile memory so they are safe in the event of a power outage
or pesky lightning-strike-wins-fight-with-power-supply.