TROUBLESHOOTING 
 

PROBLEM POSSIBLE 

CAUSE CORRECTION 

Fluid pressure too low 

Increase fluid pressure

 

Operating pressure too low

 

Increase air pressure to 70 psi (4.8 bars)

 

Dispense tip clogged or damaged

Replace tip

 

No fluid flow

 

Fluid cured in valve chamber

 

Clean valve thoroughly

 

Fluid pressure fluctuating

 

Make sure fluid pressure is constant

 

Valve operating pressure is too 
low

 

Increased valve pressure to 70 psi (4.8 
bars)

 

Valve open time is not consistent

Check to make sure the valve controller 

is providing a consistent output  

Inconsistent 

fluid flow 

Air trapped in fluid housing

 

Purge valve

 

Fluid drools after the valve 
closes, eventually stopping

 

Air trapped in fluid housing

 

Purge valve

 

Lower seal damaged or worn 

Replace lower seal 

Spool damaged 

Replace spool 

Inlet air fitting is too long, 
pushing the spool opened 

Replace air fitting 

Steady drip 

Valve re-assembled incorrectly 

Re-assemble valve follow instructions 

 
 
 
 
 
 
 

 

Summary of Contents for TS934

Page 1: ...Techcon Systems TS941 TS934 TS941A TS934A Spool Valve User Guide...

Page 2: ...cifications 3 2 Unpacking and Inspection 4 3 Description 4 4 Theory of Operation 4 5 Setup Instructions 5 6 Typical System Setup 6 7 Troubleshooting 7 8 Maintenance and Cleaning 8 9 Spare Parts and Ac...

Page 3: ...NPT female Auxiliary Air Inlet Port 1 8 NPT 1 8 NPT Minimum Air Pressure Required 70 psi 4 8 bars 70 psi 4 8 bars Maximum Fluid Pressure 2 500 psi 172 bars 2 500 psi 172 bars Operating Frequency Excee...

Page 4: ...nternal spring return makes the valve fully adaptable for use with Techcon Systems time pressure controllers 4 THEORY OF OPERATION The TS941 valve is a normally closed spool valve When air pressure is...

Page 5: ...t port Set the valve controller pressure at 70 psi 4 8 bars Set the fluid reservoir pressure Do not exceed 2 500 psi 172 bars Make sure all connections are tight Place container under the valve outlet...

Page 6: ...5130 CONTROLLER OR EQUIVALENT FLUID FEED SYSTEM PLANT AIR MUST BE PROPERLY FILTERED AND DRY IF NOT SPECIFY A 5 MICRON FILTER REGULATOR MATERIAL CONSTANT AIR PULSED AIR TS941 SPOOL VALVE 6 TYPICAL SYST...

Page 7: ...essure is too low Increased valve pressure to 70 psi 4 8 bars Valve open time is not consistent Check to make sure the valve controller is providing a consistent output Inconsistent fluid flow Air tra...

Page 8: ...cylinder 3 Clean these parts if necessary 9 Replace o rings 13 on the spool shaft material outlet block 8 and air cylinder 12 if worn or damaged 10 Remove lower seals 7 out of the outlet block and upp...

Page 9: ...installed in the valve are made of UHMWPE with EPR o ring The following seals are available PART NUMBER DESCRIPTION TSD400 56 Teflon seal with EPR expander O ring TSD400 58 Teflon seal with Viton exp...

Page 10: ...cessories T1000268 Bracket Figure 6 0 Dispensing Nozzles PART NUMBER DESCRIPTION TSD700 2 Oiler cup straight 918 006 000 Tip adapter Metal Brass and Stainless steel T1000268 Bracket 934 003 000 Adjust...

Page 11: ...om this warranty exceed the purchase price of the equipment This warranty is only valid if the defective product is returned as a complete assembly without physical damage The Manufacturer s liability...

Page 12: ...12...

Reviews: