background image

 

8

1

2

3

4

5

6

8

9

10

11

12

13

7

8.

 

MAINTENANCE AND CLEANING: 

Normally, purging the valve with appropriate flush material or solvent after use is sufficient for 
cleaning.  However some material may cause a buildup in the valve chamber, in this case periodic and 
thorough cleaning will be required. 
 

CAUTION: Make sure the fluid pressure is released before disassemble the valve. 

1)

 

Release fluid pressure 

2)

 

Disconnect fluid line 

3)

 

Disconnect valve air line 

4)

 

Remove end cap (1) 

5)

 

Pull out Piston/valve spool assembly (4) 

6)

 

Remove the spring from air cylinder (2) 

7)

 

Remove socket head cap screws (10) 

8)

 

Separate material outlet block (9), material inlet block (6) and air cylinder (3).  Clean 

these parts if necessary 

9)

 

Replace o-rings (13) on the spool shaft, material outlet block (8) and air cylinder (12) if 

worn or damaged. 

10)

 

Remove lower seals (7) out of the outlet block and upper seal (5) out of the air cylinder 

using a small screw driver 

11)

 

Clean seal seats and carefully install new seals.  It is important that seals should be 

replaced in the same orientation to prevent leaks and accelerated wear. 

12)

 

Lubricate O-rings with “Parker-o-lube” or similar grease 

13)

 

Assemble Material outlet block, Material inlet block and Air cylinder. 

14)

 

Thread Socket head cap screws into assembled valve.  Tighten uniformly to ensure 

proper valve alignment. 

15)

 

Insert the spring back into the air cylinder. 

16)

 

Insert Piston/valve spool into valve body. 

17)

 

Install air fitting to end cap. 

18)

 

Install End cap to air cylinder.  (

HAND TIGHTEN ONLY

 

 

 
 
 
 
 
 
 
 
 
 
 
 

Figure 5.0 

Summary of Contents for TS934

Page 1: ...Techcon Systems TS941 TS934 TS941A TS934A Spool Valve User Guide...

Page 2: ...cifications 3 2 Unpacking and Inspection 4 3 Description 4 4 Theory of Operation 4 5 Setup Instructions 5 6 Typical System Setup 6 7 Troubleshooting 7 8 Maintenance and Cleaning 8 9 Spare Parts and Ac...

Page 3: ...NPT female Auxiliary Air Inlet Port 1 8 NPT 1 8 NPT Minimum Air Pressure Required 70 psi 4 8 bars 70 psi 4 8 bars Maximum Fluid Pressure 2 500 psi 172 bars 2 500 psi 172 bars Operating Frequency Excee...

Page 4: ...nternal spring return makes the valve fully adaptable for use with Techcon Systems time pressure controllers 4 THEORY OF OPERATION The TS941 valve is a normally closed spool valve When air pressure is...

Page 5: ...t port Set the valve controller pressure at 70 psi 4 8 bars Set the fluid reservoir pressure Do not exceed 2 500 psi 172 bars Make sure all connections are tight Place container under the valve outlet...

Page 6: ...5130 CONTROLLER OR EQUIVALENT FLUID FEED SYSTEM PLANT AIR MUST BE PROPERLY FILTERED AND DRY IF NOT SPECIFY A 5 MICRON FILTER REGULATOR MATERIAL CONSTANT AIR PULSED AIR TS941 SPOOL VALVE 6 TYPICAL SYST...

Page 7: ...essure is too low Increased valve pressure to 70 psi 4 8 bars Valve open time is not consistent Check to make sure the valve controller is providing a consistent output Inconsistent fluid flow Air tra...

Page 8: ...cylinder 3 Clean these parts if necessary 9 Replace o rings 13 on the spool shaft material outlet block 8 and air cylinder 12 if worn or damaged 10 Remove lower seals 7 out of the outlet block and upp...

Page 9: ...installed in the valve are made of UHMWPE with EPR o ring The following seals are available PART NUMBER DESCRIPTION TSD400 56 Teflon seal with EPR expander O ring TSD400 58 Teflon seal with Viton exp...

Page 10: ...cessories T1000268 Bracket Figure 6 0 Dispensing Nozzles PART NUMBER DESCRIPTION TSD700 2 Oiler cup straight 918 006 000 Tip adapter Metal Brass and Stainless steel T1000268 Bracket 934 003 000 Adjust...

Page 11: ...om this warranty exceed the purchase price of the equipment This warranty is only valid if the defective product is returned as a complete assembly without physical damage The Manufacturer s liability...

Page 12: ...12...

Reviews: