background image

 

4

 

2

2.

 

UNPACKING AND INSPECTION 

Carefully unpack the valve and examine the items contained in the carton. 
These will include: 

 

Valve Assembly 

 

User Guide 

 

Fitting and Valve Air Hose 

Inspect the unit for any damaged which may have occurred in transit.  If such damage has occurred, 
notify the carrier at once.  Claim for damage must be made by the consignee to the carrier, and should be 
reported to the manufacturer. 

 

3.

 

DESCRIPTION 

The TS941 spool valve is based on a balanced spool design for a fast “ON/OFF” dispensing action.  The 
hardened spool slides in reinforced UHMWPE seals and it suitable for use with fluids having viscosity 
of 100 to over 3,000,000 cps at pressure up to 2,500 psi (172 bars).  An internal spring return makes the 
valve fully adaptable for use with Techcon Systems time/pressure controllers. 
 

4.

 

THEORY OF OPERATION 

The TS941 valve is a normally closed spool valve.  When air pressure is applied at air inlet port (1), the 
spool assembly (2) moves forward to the open position, allowing the fluid to flow from the fluid inlet 
port (3) to the fluid outlet port (4).  Relieving the input air pressure allows the return spring (5) to pull 
the spool assembly back in the close position, stopping the fluid flow.  During the closing position, the 
spool movement creates a “suck-back” anti-drip feature. 
 
An Oil chamber (6) is provided above the upper seal to create an additional liquid seal that will prevent 
moisture from being carried on the spool.  The auxiliary air inlet port (7) is provided so that the valve 
may be connected for air closing with or without the spring. 

 
 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 

 

Open Position 

Closed Position 

Figure 2.0 

Summary of Contents for TS934

Page 1: ...Techcon Systems TS941 TS934 TS941A TS934A Spool Valve User Guide...

Page 2: ...cifications 3 2 Unpacking and Inspection 4 3 Description 4 4 Theory of Operation 4 5 Setup Instructions 5 6 Typical System Setup 6 7 Troubleshooting 7 8 Maintenance and Cleaning 8 9 Spare Parts and Ac...

Page 3: ...NPT female Auxiliary Air Inlet Port 1 8 NPT 1 8 NPT Minimum Air Pressure Required 70 psi 4 8 bars 70 psi 4 8 bars Maximum Fluid Pressure 2 500 psi 172 bars 2 500 psi 172 bars Operating Frequency Excee...

Page 4: ...nternal spring return makes the valve fully adaptable for use with Techcon Systems time pressure controllers 4 THEORY OF OPERATION The TS941 valve is a normally closed spool valve When air pressure is...

Page 5: ...t port Set the valve controller pressure at 70 psi 4 8 bars Set the fluid reservoir pressure Do not exceed 2 500 psi 172 bars Make sure all connections are tight Place container under the valve outlet...

Page 6: ...5130 CONTROLLER OR EQUIVALENT FLUID FEED SYSTEM PLANT AIR MUST BE PROPERLY FILTERED AND DRY IF NOT SPECIFY A 5 MICRON FILTER REGULATOR MATERIAL CONSTANT AIR PULSED AIR TS941 SPOOL VALVE 6 TYPICAL SYST...

Page 7: ...essure is too low Increased valve pressure to 70 psi 4 8 bars Valve open time is not consistent Check to make sure the valve controller is providing a consistent output Inconsistent fluid flow Air tra...

Page 8: ...cylinder 3 Clean these parts if necessary 9 Replace o rings 13 on the spool shaft material outlet block 8 and air cylinder 12 if worn or damaged 10 Remove lower seals 7 out of the outlet block and upp...

Page 9: ...installed in the valve are made of UHMWPE with EPR o ring The following seals are available PART NUMBER DESCRIPTION TSD400 56 Teflon seal with EPR expander O ring TSD400 58 Teflon seal with Viton exp...

Page 10: ...cessories T1000268 Bracket Figure 6 0 Dispensing Nozzles PART NUMBER DESCRIPTION TSD700 2 Oiler cup straight 918 006 000 Tip adapter Metal Brass and Stainless steel T1000268 Bracket 934 003 000 Adjust...

Page 11: ...om this warranty exceed the purchase price of the equipment This warranty is only valid if the defective product is returned as a complete assembly without physical damage The Manufacturer s liability...

Page 12: ...12...

Reviews: