5. PROGRAMMING OPERATIONS
EO1-11152
5.2 Programming Operations Added for In-line Terminals
5- 2
5.2 Programming Operations Added for In-line Terminals
5.2.1 Terminal Connection Table Setting (Submode 69)
This submode is required for In-line services. The In-line ID No., Register No. and IP Address of each terminal
(including the Master Terminal) can be programmed here.
Any time outside a sale
Mode
Lock:
SET and IN-LINE Lamp illuminated
69
[@/FOR]
|In-line ID No.| [ST]
|Store/Register No.| [#] |IP
Address|
[#]
[AT/TL]
NOTES: 1.
In-line ID No.:
Master Terminal ... 01 (fixed)
Backup Master Terminal (if connected) ... 02 (fixed)
Satellite Terminals ... 03 to 16 (max. 14 terminals)
2. The In-line ID No. and Register No. of each terminal to be set here must be the same as those
programmed for the terminal in IN-LINE TERMINAL ID SETTING (Submode 77) in this chapter
and STORE/REGISTER NO. SETTING (no submode) in Chapter 6 of the Programming Manual
for stand-alone level.
3.
IP Address: 12 digits (000.. 000 to 255.. 255)
ex) To set the IP Address 192.168.0.252……….Enter 192168000252
4. To delete an individual terminal from the Terminal Connection Table, enter 0 in place of the In-
line ID No., then enter Register No..
69
[@/FOR] 0
[ST]
|Store/Register No.| [#]
[AT/TL]
5.
To delete the entire Terminal Connection Table once set, operate:
69 [@/FOR] 0
[AT/TL]
6. If a deleting operation (individual or entire deletion) is performed, the files occupied by the
deleted terminal(s) (such as Floating Cashier File, etc.) is canceled. Therefore, a deleting
operation should be performed only when the system is to be re-built or a terminal is to be
detached from the system.
Example)
To set Master Terminal and Satellite Terminal in the Connection
Table (total of two terminals in the in-line system):
Master Terminal
In-line ID No. 1
Register No. 111101
IP Address 192.168.0.251
Satellite Terminal
In-line ID No. 3
Register No. 333303
IP Address 192.168.0.253
Key Operation: Mode
Lock
SET and IN-LINE Lamp illuminated,
enter 69, depress [@/FOR].
01
[ST]
(Master In-line ID No.)
111101
[#]
(Master Register No.)
192168000251
[#]
(Master IP Address)
03
[ST]
(Satellite In-line ID No.)
333303
[#]
(Satellite Register No.)
192168000253
[#]
(Satellite IP Address)
[AT/TL]
(Complete this Submode)
OPERATION
CONDITION
2 digits (01 to 16)
(
NOTES 1 & 2 below)
Max. 6 digits
0 to 999999
(
NOTE 2 below)
12 digits
(
NOTE 3 below)
* For sequentially
programming In-
line ID Nos, the In-
line ID specification
can be skipped.
*
Repeat for other terminals to be connected, including the Master Terminal itself. (Max. 16 terminals)
7(& 6725(
7(& 6725(
3($&+ '5,9(
3+21(
2SHQ DP WR SP
&ORVHG HYHU\ :HGQHVGD\
681
3
3
70
Summary of Contents for MA-1595-1 SERIES
Page 1: ...TEC Electronic Cash Register MA 1595 1 SERIES Owner s Manual...
Page 5: ...1 STAND ALONE LEVEL OPERATOR S GUIDE...
Page 87: ...2 STAND ALONE LEVEL MANAGER S GUIDE...
Page 168: ...3 M S LEVEL OPERATOR S GUIDE...
Page 173: ...4 M S LEVEL MANAGER S GUIDE...
Page 216: ......
Page 217: ......
Page 218: ...E PRINTED IN MALAYSIA EO1 11152B...