9. BACKUP FUNCTION
EO1-11152
9. BACKUP FUNCTION
9- 3
• While the backup error flag is on, the following operation is performed.
1. The Master Terminal gives a short beep at the timing when the long receipt is printed to warn that a
backup error has occurred.
2. The RTR declaration cancel operation results in compulsory manual data copy error. (The error
indication “PLEASE BACK UP” is displayed.)
In this case, the RTR declaration is not canceled until the manual data copy operation is performed.
• There are two timings cases the backup error flag is turned off.
1. The backup data is properly backed up according to the backup data update process.
2. The Backup Master Terminal (ID No. 2) is deleted from the terminal connection table.
6) Backup Data Update Process
(This is a process required when the backup data stored in the Backup Master Terminal is not updated
properly due to an error.)
• The method processing backup error is selected according to the program option setting. Even if the
automatic data copy operation is selected, data copy can be performed manually.
1. Automatic data copy (program option)
When the backup error flag is on (or turned on), the Master Terminal automatically sends to the Backup
Master Terminal the file in which the error has occurred, and updates the backup data.
2. Manual data copy (program option)
The backup data is updated by the manual operations of the operator.
* When the backup data is being updated, inquiries from terminals may result in a “MASTER IS BUSY” error.
* When a “MASTER IS BUSY” error occurs, clear the error using the [C] key. Then, update the backup data
again after the master job (backup process) is complete.
* Only the files with the backup error flag turned on are sent to the Backup Master Terminal to update the
backup data.
* When the master job is being done on the Master Terminal ([RTR] key is turned on), backup data is not
checked or updated.
* If the backup error flag is on when the master job is complete on the Master Terminal ([RTR] key is turned
off; the INLINE lamp is off), manual data copy becomes compulsory.
7) Manual Copy of Backup Data
OPERATION ON MASTER TERMINAL: Mode
Lock: Z and IN-LINE Lamp illuminated
900
[AT/TL]
Backup Data
Response
M
BM
Summary of Contents for MA-1595-1 SERIES
Page 1: ...TEC Electronic Cash Register MA 1595 1 SERIES Owner s Manual...
Page 5: ...1 STAND ALONE LEVEL OPERATOR S GUIDE...
Page 87: ...2 STAND ALONE LEVEL MANAGER S GUIDE...
Page 168: ...3 M S LEVEL OPERATOR S GUIDE...
Page 173: ...4 M S LEVEL MANAGER S GUIDE...
Page 216: ......
Page 217: ......
Page 218: ...E PRINTED IN MALAYSIA EO1 11152B...