Version 12.11.2013 TEC-6050-2
CANTEC-F2 V5
P
a
g
e
10
CAN-bus
4.2.
Programmable outputs/inputs configuration (MENU 2)
In MENU 2, the programmable outputs and inputs can be set to other functions than the
predefined factory defaults (see chapter 2.).
Follow the below programming sequence to change or check programmable output/input
functions of MENU 2:
1.
Turn on ignition.
2.
To enter MENU 2, press the programming button 12 times. The unit confirms with
four light signals.
3.
After selecting the programmable output’s/input’s option no. desired to
change/check (see chapters 4.2.1. or 4.2.2., tables 3 or 5), press the programming
button for the number of times corresponding with the option number (no.). The unit
confirms with the same amount of light signals.
4.
To enter the programming mode, press and hold the brake pedal*. The unit informs
about the status of the chosen option by the corresponding number of LED light
signals. There is no countdown until programming mode is deactivated.
5.
Change the option’s function no. by pressing the programming button for the
number of times required to move from current setting to the required setting value
while the last setting value is followed by the first one. (e.g., in order to change
option no. 5 (positive output – pin 4) from factory default function no. 13 - engine on
to function no. 21 - brake, press the programming button 8 times). The unit confirms
new the setting value with the corresponding number of light signals.
6.
Exceptions: programmable output functions no. 8, 10 and 15 require additional
programming sub-sequence, see corresponding function no. in table 4.
7.
Release the brake pedal. The unit’s light indication changes from option setting value
back to option number. It is possible to proceed with programming the next option
or to leave the programming mode.