PRODUCER 3
06/18/97
Lighting Control Console
page
TEATRONICS LIGHTING CONTROLS,
TEATRONICS LIGHTING CONTROLS,
INC.
INC.
11
OPERATION
(continued)
RECORD MODE
/Recording Dimmer Assignments (continued)
Example 4
Using the clear key to correct mistakes.
In this example we will make two errors when entering the patch. The clear key will be used to
correct both mistakes. What we wish to do is assign dimmer 15 to channel 5 at 100%.
KEY STROKE
DISPLAY
RESULT
REC
Record Mode
Console in Record Mode
CHN
Channel --
Waiting for Channel Input
14
Ch14 Dimmer---
Waiting for Dimmer Input
Entry error, correct by using CLEAR
(Clear Channel 14)
CLEAR
Channel --
Waiting for Channel Input
15
Ch15 Dimmer---
Waiting for Dimmer Input
Enter first Dimmer Number, 15
115
Ch15 Dimmer115
Waiting for level or ENTER
AT
Ch15 Dm 115 @--
Waiting for level
100
Ch15 Dm 115 @FL
Waiting for more or Enter
Entry error, correct by using CLEAR
(Clear Dimmer 115)
CLEAR
Ch15 Dm 115 @--
Waiting for level
CLEAR
Ch15 Dimmer---
Waiting for Dimmer Input
015
Ch15 Dimmer015
Waiting for level or ENTER
AT
Ch15 Dm 015 @--
Waiting for level
100
Ch15 Dm 015 @FL
Waiting for more or Enter
ENTER
Record Mode
Console in Record Mode
Example 5
Removing a dimmer from a channel.
Dimmers are removed from a particular channel by assigning them to another channel. If a
dimmer is not to be used in a certain patch, it may be assigned to the "hidden" channel, channel
zero. This example removes dimmers 7 and 44 from their previous assignments and assigns
them to channel zero.
KEY STROKE
DISPLAY
RESULT
REC
Record Mode
Console in Record Mode
CHN
Channel --
Waiting for Channel Input
00
Ch00 Dimmer---
Waiting for Dimmer Input
Enter first Dimmer Number, 7
007
Ch00 Dimmer007
Waiting for level or ENTER
AND (&)
Ch00 Dimmer---
Waiting for Dimmer Input
Enter next Dimmer Number, 44
044
Ch00 Dimmer044
Waiting for level or ENTER
ENTER
Record Mode
Console in Record Mode