PRODUCER 3
06/18/97
Lighting Control Console
page
TEATRONICS LIGHTING CONTROLS,
TEATRONICS LIGHTING CONTROLS,
INC.
INC.
10
OPERATION
(continued)
RECORD MODE
/Recording Dimmer Assignments (continued)
Example 3
Assigning a series of dimmers to a channel at various levels.
This example assigns the following dimmer numbers to channel number 15: dimmer 15 at
100%, dimmers 190 and 192 at 80%, dimmers 147 through 151 at 60%, and dimmers 1 and 5 at
100%.
KEY STROKE
DISPLAY
RESULT
REC
Record Mode
Console in Record Mode
CHN
Channel --
Waiting for Channel Input
15
Ch15 Dimmer---
Waiting for Dimmer Input
Enter first Dimmer Number, 15
015
Ch15 Dimmer015
Waiting for level or ENTER
AT
Ch15 Dm 015 @--
Waiting for level
100
Ch15 Dm 015 @FL
Waiting for more or Enter
AND (&)
Ch15 Dimmer---
Waiting for Dimmer Input
Enter next Dimmer Number, 190
190
Ch15 Dimmer190
Waiting for level or ENTER
THRU
Ch15 Dimmer---
Waiting for Dimmer Input
192
Ch15 Dimmer192
Waiting for level or ENTER
AT
Ch15 Dm 192 @--
Waiting for level
80
Ch15 Dm 192 @80
Waiting for more or Enter
AND (&)
Ch15 Dimmer---
Waiting for Dimmer Input
Enter next Dimmer Number, 147
147
Ch15 Dimmer147
Waiting for level or ENTER
THRU
Ch15 Dimmer---
Waiting for Dimmer Input
151
Ch15 Dimmer151
Waiting for level or ENTER
AT
Ch15 Dm 151 @--
Waiting for level
60
Ch15 Dm 151 @60
Waiting for more or Enter
AND (&)
Ch15 Dimmer---
Waiting for Dimmer Input
Enter next Dimmer Number, 001
001
Ch15 Dimmer001
Waiting for level or ENTER
AND (&)
Ch15 Dimmer---
Waiting for Dimmer Input
005
Ch15 Dimmer005
Waiting for level or ENTER
AT
Ch15 Dm 005 @--
Waiting for level
100
Ch15 Dm 20 @FL
Waiting for more or Enter
ENTER
Record Mode
Console in Record Mode