409-10204
Rev G
8
of 23
2.2.
Electrical Description
The PN 2161400-[ ] and PN 2161500-[ ] machine electrical components consist of the operator control panel,
the motor, and the CPU/motor controller and safety circuit package. The machine operates on 100/240 Vac,
50/60 Hz, single-phase current with ground. The machine will automatically detect the supply voltage and
adjust the controller accordingly.
The operator control panel (Figure 6) is mounted on the left side of the machine frame. The control panel
consists of five button membrane key pad and a two line by eight column display. The membrane key pad has
icons representing the function of each button.
Figure 6
A main power switch/circuit breaker (Figure 6) is located on the front of the control panel. The main power
switch/circuit breaker connects ac power to the control system. The CPU/motor controller and safety circuit are
located in the electrical control box.
2.3.
Machine Guard
A guard is installed to provide protection for the operator while maintaining proper visibility of the work area.
The guard swings open to allow easy access for applicator installation and setup. A safety switch on the guard
prevents machine operation if the guard door is open.
3.
RECEIVING INSPECTION AND INSTALLATION
3.1.
Receiving Inspection
These machines are thoroughly inspected during and after assembly. A final series of inspections is made to
insure the proper machine functioning before packaging and shipping.
To protect against damage that may have occurred during shipment, remove the machine from the crate
(paragraph 3.2.) and carefully inspect the machine for damage. If damage is evident, file a claim against the
carrier and notify TE immediately.
Membrane Keypad
Button(s)
Display
ON/OFF Switch