KF139 Issue 17 © 2014
Page 1 of 12
®
K29 / K32 FLEXIGUN
INSTRUCTION MANUAL
Thank you for purchasing a Macnaught K29 or K32
single hand operated grease gun.
Please read and retain this instruction sheet to assist
you in the operation and maintenance of this quality
product.
Your Macnaught Flexigun is a pistol grip type grease gun
complete with high pressure flexible grease hose for easy
access to those hard to reach grease points.
The Flexigun is designed for use with 400g (K32) or 450g
(K29) cartridges or bulk grease. The filler/bleeder valve in
the head also allows clean filling from 20kg (35lb) grease
pails using a Macnaught “J3” Grease Gun Filler Pump.
The “variable stroke” feature of this grease gun allows you
to achieve higher greasing pressures using short piston
strokes or high volume with a full stroke
.
Caution must be observed when either
unscrewing the barrel or unscrewing the pull handle
from the follower rod as the large follower spring
inside the barrel is energised.
Select the correct Follower position
Most Macnaught grease guns are equipped with a single
lip, two position follower so you can use either cartridge or
bulk grease with minimum grease by-passing the follower.
How to select Follower position
Fig 1
Loading Gun with Grease
If Using Cartridge Grease:
1) Select the correct follower position (see Fig 1).
2) Unscrew Barrel and “Lock” Follower (see Fig 4).
3) Pull Follower Rod out until groove in rod can be moved
into slot in Barrel End Cap, lock the rod into end cap.
4) Remove both caps from grease cartridge. Insert into
barrel, larger open end first. Screw barrel to head tightly.
If Using Bulk Grease:
1) Select the correct follower position (see Fig 1).
2) Unscrew Barrel and lock Follower (see Fig 4).
3) Insert Barrel into grease and slowly pull Follower
Rod out while pushing the Barrel further into grease.
(see Fig 2).
Fig 2
Fig 3
4) When groove in rod lines up with slot in end cap, lock
rod in end cap.
5) Wipe excess grease from outside of Barrel then
screw Barrel to head tightly.
6) Bleed air from grease (see Fig 5).
If Using J3 filler Pump:
1) Ensure the Follower is set in the bulk position
(see Fig 1).
2) “Lock” Follower to Follower Rod (see Fig 4).
3) Push Filler/Bleeder Valve into J3 Pump outlet (see
Fig 3).
6) Bleed air from grease (see Fig 5).
Introduction
Product Description
CAUTION
5) Ensure the seal washer is in position and screw the
barrel to the head tightly.
Includes m odels
K29-01
K29-01-11
K29-02
K29-12
K29-17
K32-01
K32-03