TE Connectivity Confidential & Proprietary. Do not reproduce or distribute.
3. Attachment hardware Assy and back plate Assy procedure
3.3 Assemble bolster plate on PCB
Attach bolster plate on PCB top side. gasket side down, on the board
Holding bolster plate to maintain alignment, fully fasten nut#1 first with 0.904N.m(8in-lbf) of torque.
Tighten the nuts in any order
Tool: Electric torque
T-20 Torx bit
Torque:0.904N.m or
8 in-ibf
IMPORTANT: Tighten the nuts in any order.
Fig.5
6
Instruction Sheet
411-115008 Rev.A
20th Mar’20