Electrical
CBP/CSP
Appropriate machine grounding is critical for safe operation. Therefore, an external copper ground
conductor with a minimum cross section of 2 mm
2
, must be connected to the machine’s
PE point. This is
located on the right-
side frame and is labeled with “PE”. Be aware that electrical hazards exist where
labeled.
The main power disconnect switch with “lock
-
out” function is provided on the right side of the machine and
is clearly marked.
CMP
Due to power line filter components the leakage current is higher than 10mA. Therefore, a threaded bolt is
fixed to the machine frame and labeled with a ground symbol. A separate additional ground line has to be
connected to that point. The wire cross section must be at least 10 mm
2
.
The main power disconnect switch is provided in the rear panel of the machine and is clearly marked.
When it is in the “ON” position, it is mechanically interlocked to prevent the access door from being
opened. When it is in the “OFF” position, the switch
may be locked in position by inserting a padlock into
one of the three locking locations (see Figure 2). In addition to the mechanical interlock, the door is
equipped with a keyed lock.
Figure 2
Eye/Ear Protection
Eye protection should be worn at all times when operating or servicing this machine. In the event a connector is
crushed during the pressing operation, pieces of the connector could become airborne.
NOTE
: The laser
sensor does not require eye protection use (see Figure 3).
No ear protection is required. Emission sound pressure level at workstation does not exceed 70 dB(A).
Figure 3
Lock Out/Tag Out