93
7.8.8 Status Commands
Refer to section 9.3.1, 9.3.2 for Register definitions.
#
Command
Description
1
STT?
Reads the complete power supply status.
Returns ASCII characters representing the following data, separated by commas:
MV<actual (measured) voltage> PC<programmed (set) current>
PV<programmed (set) voltage> SR<status register, 4-digit hex>
MC<actual (measured) current> FR<fault register, 4-digit hex>
Example response: MV(650.05),PV(650.05),MC(2.6000),PC(2.6500),SR(0030),FR(0000)
2
FLT?
Reads Fault Conditional Register. Return 4-digit hex.
3
FENA
Set Fault Enable Register using 4-digit hex.
4
FENA?
Reads Fault Enable Register. Returns 4-digit hex.
5
FEVE?
Reads Fault Event Register. Returns 4-digit hex. Clears bits of Fault Event Register.
6
STAT?
Reads Status Conditional Register. Returns 4-digit hex.
7
SENA
Sets Status Enable Register using 4-digit hex.
8
SENA?
Reads Status Enable Register. Returns 4-digit hex.
9
SEVE?
Reads Status Event register. Returns 4-digit hex. Clears bits of Status Event register.
7.8.7 Auxiliary Commands
SOP
Sets SO polarity ”SO 1/ON” –Positive (default), ”SO 0/OFF”-Negative
SOP?
Returns the SO polarity
RIE
Remote Interlock (Inhibit) enable. ”RIE 1/ON”-Enable, ”RIE 0/OFF”-Disable”
RIE?
Returns Interlock enable status. ”ON” –interlock enable, ”OFF”-interlock disable.
FRST
Factory reset command. This command cover *RST command and additional settings. Sets factory
default. This command breaks communication. Refer to Table
5-7.
MP?
Reads the actual output power. Returns 5 digit string.
REL1
Set auxiliary programmed pin state J3-1. ”REL1 1/ON”- High, REL1 0/OFF”- Low
REL1?
Response auxiliary programmed pin state J3-1.
REL2
Set auxiliary programmed pin state J3-6, ”REL2 1/ON”- High, REL2 0/OFF”- Low
REL2?
Response auxiliary programmed pin state J3-6
Summary of Contents for Z160-1.3
Page 5: ...This page intentionally left blank...
Page 27: ...26 Pages 26 33 are reserved for Z600 800W...
Page 28: ...27 Pages 26 33 are reserved for Z600 800W...
Page 29: ...34 2 6 Z200W 400W 600W 800W Outline Drawing...
Page 30: ...35 2 7 Z200W 400W 600W 800W Optional IEEE Isolated Analog Interface Outline Drawing...
Page 31: ...36 This Page intentionally left blank...
Page 137: ...NOTES...
Page 138: ...NOTES...
Page 139: ...NOTES...