129
9.3.2 Status Register
The status register sets a bit when status changes (Refer to Table 9-2). The bit is cleared when the
condition is removed.
Bit Number
Decimal Value
Bit Symbol
Description
0
1
CV
Set high if Constant Voltage Operation
1
2
CC
Set high if Constant Current Operation
2
4
NFL
No fault
3
8
TW
Trigger wait
4
16
AST
Auto Start Enabled
5
32
FBE
Foldback enable
6
64
LSC
List step complete
7
128
LOC
Local / Remote
8
256
UVP Ena
Under voltage Protect enabled
9
512
ILC Ena
Interlock Enabled
10
1024
11
2048
FBC
Foldback CC mode enabled
12
4096
AVP
Remote Analog Voltage Programming mode
13
8192
ACP
Remote Analog Current Programming mode
14
16384
DWE
The list step is active (dwelling)
15
32768
Reserved
Table 9-2: Bit Configuration of Operation
9.4 Conditional, Enable and Event Registers
9.4.1 Conditional Registers.
The condition registers show a snapshot of the power supply state at the present time. Some
faults or mode changes occur and clear quickly before the control computer can detect them.
The change may be latched in EVENT REGISTERS so the computer can detect them even if they
cleared quickly.
9.4.2 Event Registers.
Bits are sent to the Event register when a fault or mode change occurs. The bit remains set until
the control computer reads the Event register or clears it. The control computer cannot tell if the
fault or mode change occurred more than once since the last time the Event register was read.
9.4.3 Enable Register
The Status and Fault Enable registers are set by the user to enable SRQs in the event of changes
in power supply status or fault.
9.5 Service Request
A SRQ will be sent when the contents of at least one of the event registers changes from all zeroes
to any bit(s) set. When SRQ occurs, power supply sends ”!nn” message (nn-power supply address).
Summary of Contents for Z160-1.3
Page 5: ...This page intentionally left blank...
Page 27: ...26 Pages 26 33 are reserved for Z600 800W...
Page 28: ...27 Pages 26 33 are reserved for Z600 800W...
Page 29: ...34 2 6 Z200W 400W 600W 800W Outline Drawing...
Page 30: ...35 2 7 Z200W 400W 600W 800W Optional IEEE Isolated Analog Interface Outline Drawing...
Page 31: ...36 This Page intentionally left blank...
Page 137: ...NOTES...
Page 138: ...NOTES...
Page 139: ...NOTES...