PH
PH
B-307
・All specifications are subject to change without notice.
PH100S48
PH100S48 Specifications
PH
100S48
0
20
40
60
80
100
−20
0
20
40
60
85 100
型名 PH100S48
Baseplate Temperature(℃)
Load
(%)
Derating Curve
ITEMS/UNITS
MODEL PH100S48-3.3 PH100S48-5 PH100S48-12 PH100S48-15 PH100S48-24 PH100S48-28
Input
Voltage Range
V
DC36 - 76
Efficiency (typ)
(*1)
%
74
81
83
84
85
Current (typ)
(*1) A
1.86
2.57
2.53
2.49
2.47
Output
Nominal Voltage
VDC
3.3
5
12
15
24
28
Maximum Current
A
20
8.4
6.7
4.2
3.6
Maximum Power
W
66
100
100.8
100.5
100.8
Voltage Setting Accuracy (*1)
%
±
1
Maximum Line Regulation (*2) mV
20
48
60
96
112
Maximum Load Regulation (*3) mV
40
96
120
192
224
Temperature Coefficient
0.02%/
℃
Maximum Ripple & Noise (*9) mVp-p
100
150
240
280
Voltage Adjustable Range (*8)
+10%, -10% (At 48VDC Input)
Function
Over Current Protection (*4)
105 - 150%
Over Voltage Protection (*5)
165 - 240%
125 - 145%
Remote Sensing
Possible
Remote ON/OFF Control (*8)
Possible (SHORT: ON OPEN: OFF)
Parallel Operation
―――――
Series Operation
(*8)
Possible
Environment
Operating Temperature (*6)
℃
-20 to +85 (Baseplate) Ambient temperature min=-20
Storage Temperature
℃
-40 to + 85
Operating Humidity
%
RH
30 - 95 (No dewdrop)
Storage Humidity
%
RH
10 - 95 (No dewdrop)
Vibration
At no operating, 10-55Hz amplitude (sweep for 1min)
0.825mm constant (maximum 49.0m/s²) X, Y, Z 1h each
Shock
196.1m/s² (In package)
Cooling
(*7)
Conduction cooled
Isolation
Withstand Voltage
Input-Baseplate : 2.5kVAC, Input-Output : 3kVAC(20mA) for 1min
Output-Baseplate : 500VDC for 1min
Isolation Resistance
More than 100M
Ω
at 25
℃
and 70%RH Output-Baseplate...500VDC
Standards Safety Standards
Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1
Mechanical
Weight (typ)
g
150
Size (W x H x D)
mm
62 x 12.7 x 86 (Refer to outline drawing)
(*1) At 48VDC and maximum output current.
(*2) 36 - 76 VDC, constant load.
(*3) No load - full load, constant input voltage.
(*4) Constant current limiting with automatic recovery.
(*5) Inverter shutdown method, manual reset.
(*6) Ratings - Refer to derating curve below.
- Load(%) is percent of maximum output current.
(*7) Heatsink has to be chosen according to instruction manual.
(*8) Refer to instruction manual.
(*9) External components are needed for operation.
(Refer to basic connection and instruction manual.)