PH
PH
B-330
・All specifications are subject to change without notice.
【PH50S, PH75S, PH100S, PH150S, PH300S, PH600S】
Block Diagram
【PH50S, PH75S, PH100S, PH150S, PH300S, PH600S】
Switching frequency (fixed)
PH50S24:315kHz
PH50S48, PH75S48:330kHz
PH100S48, PH150S48:300kHz
PH50S110, PH75S110, PH150S110:330kHz
PH50S280, PH75S280, PH100S280, PH150S280:330kHz
PH300S, PH600S:200kHz
*2 Applicable to PH300S, PH600S only
*3 Please note that the output shuts down when input interruption is less than 1s for PH50S, 75S, 100S, and 150S series.
In case of input interruption, please use F-type PHs.
Sequence Time Chart
PH
50S, 75S, 100S, 150S, 300S, 600S
OVP Trip
INPUT ON
INPUT OFF
INPUT ON
INPUT OFF
INPUT ON
OTP ON
Input Voltage
Output Voltage
*1
ON/OFF
Control
*1Level
4≦H≦35(V)
or Open
0≦L≦0.8(V)
or Short
REMOTE OFF
REMOTE ON
OCP ON
OCP RESET
H
L
H
L
*2
IOG
H
L
OCP Set Point
INPUT OFF
INPUT ON
OVP Set Point
*3
+Vin
CNT
−Vin
+V
TRM
+S
PH100S
PH150S
PH300S
PH600S
only
−S
−V
OCP
Switching
Rectifier
Output Filter
OVP
Voltage
Sensing
OTP
IOG
Baseplate
PH300S
PH600S
only
CS
Input Filter
ON/OFF Control
Control Circuit
Summary of Contents for PH Series
Page 58: ...B 356...