PH
PH
B-326
・All specifications are subject to change without notice.
PH600S280
PH600S280 Specifications
PH
600S280
0
20
40
60
80
100
−
20 0
20
40
60
80 100
Baseplate Temperature (℃)
Load (%)
85
型名 PH600S280
Derating Curve
ITEMS/UNITS
MODEL PH600S280-3.3 PH600S280-5 PH600S280-12 PH600S280-15 PH600S280-24 PH600S280-28 PH600S280-48
Input
Voltage Range
V
DC200 - 400
Efficiency (typ)
(*1)
%
80
84
88
Current (typ)
(*1) A
1.47
2.13
2.44
Output
Nominal Voltage
VDC
3.3
5
12
15
24
28
48
Maximum Current
A
100
50
40
25
21.5
12.5
Maximum Power
W
330
500
600
602
600
Voltage Setting Accuracy (*1)
%
±
1
Maximum Line Regulation (*2) mV
20
48
60
96
112
192
Maximum Load Regulation (*3) mV
40
96
120
192
224
384
Temperature Coefficient
0.02%/
℃
Maximum Ripple & Noise (0~
+
100
℃
) (*9) mVp-p
100
150
240
280
480
Maximum Ripple & Noise (
-
20~0
℃
) (*9) mVp-p
150
225
360
420
720
Voltage Adjustable Range (*10)
+20%, -10%
±
10%
+20%, -10%
Function
Over Current Protection (*4)
105 - 150%
Over Voltage Protection (*5)
140-170%
125 - 145%
Remote Sensing
(*8)
Possible
Remote ON/OFF Control (*8)
Possible (SHORT: ON OPEN: OFF)
Parallel Operation
(*11)
Applicable with CS signal
Series Operation
(*8)
Possible
I.O.G. Signal
(*8)
Built-in (Open collector output)
Environment
Operating Temperature (*6)
℃
-20 to +100 (Baseplate) Ambient temperature min=-20
℃
-20 to +85: 100%, +100: 80%
Storage Temperature
℃
-40 to + 100
Operating Humidity
%
RH
30 - 95 (No dewdrop)
Storage Humidity
%
RH
10 - 95 (No dewdrop)
Vibration
At no operating, 10-55Hz (sweep for 1min)
Amplitude 0.825mm constant (maximum 49.0m/s²) X, Y, Z 1h each
Shock
196.1m/s²
Cooling
(*7)
Conduction cooled
Isolation
Withstand Voltage
Input-Baseplate : 2.5kVAC, Input-Output : 3kVAC(20mA) for 1min
Output-Baseplate : 500VDC for 1min
Isolation Resistance
More than 100M
Ω
at 25
℃
and 70%RH Output-Baseplate...500VDC
Standards Safety Standards
Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950
Mechanical
Weight (typ)
g
400
Size (W x H x D)
mm
146 x 12.7 x 86 (Refer to outline drawing)
(*1) At 280VDC and maximum output current.
(Baseplate temperature = +25
℃
)
(*2) 200 - 400VDC, constant load.
(*3) No load - full load, constant input voltage.
(*4) Constant current limiting with automatic recovery.
(*5) Inverter shutdown method, manual reset with CNT signal.
(*6) Ratings - Refer to derating curve below.
- Load(%) is percent of maximum output
current.
Baseplate : Refer to instruction manual.
(*7) Heatsink has to be chosen according to instruction
manual.
(*8) Refer to instruction manual.
(*9) External components are needed for operation.
(Refer to basic connection and instruction manual.)
(*10) At 280VDC input.(Refer to instruction manual.)
(*11) External circuit is needed for operation .
(Refer to instruction manual.)
Summary of Contents for PH Series